🌿 Dust in waste gases — measurement of concentration and mass flow rate by the gravimetric method (PN-Z-04030-7)

Environment PN-Z-04030-7

In short

A national standard for the manual, gravimetric measurement of dust in waste gases in the concentration range from 0. The test is performed according to PN-Z-04030-7:1994; Concentration range: from 0.001 to 100 g/m³ (i.e. from 1 mg/m³ to 100 g/m³) — from the PKN catalogue card. The procedure comprises 7 steps; it is used for: Measurements of dust emission from stationary sources — boiler houses, heating plants, industrial installations, Calibration and checking of automatic dust monitors installed on flue gas ducts, Assessment of the effectiveness of dedusting equipment — measurement upstream and downstream of the equipment.

At a glance

  • Standard: PN-Z-04030-7:1994
  • Category: Environment
  • Procedure steps: 7
  • Concentration range: from 0.001 to 100 g/m³ (i.e. from 1 mg/m³ to 100 g/m³) — from the PKN catalogue card
  • Type of measurement: THREE types with different requirements: accurate, technical, indicative — citing the standard alone does not say which was used
  • Nature of the method: Manual, gravimetric; permitted for the calibration of automatic measurements

Overview

SCOPE FROM THE PKN CATALOGUE CARD, QUOTED VERBATIM (our translation): "The standard concerns manual measurements in the range of dust concentrations in waste gases from 0.001 to 100 g/cubic m. The method may be used for the calibration of automatic measurements. Requirements are given for three types of measurements: accurate, technical and indicative. The Annexes and Additional information give guidelines for determining auxiliary quantities and for assessing errors. Auxiliary tables and diagrams of typical measuring systems are included".

THE MOST COMMON MISTAKE: THIS IS NOT A STANDARD ON DUST AT THE WORKPLACE. The PN-Z-04030 series covers several sheets with very different subjects. Sheets 05 and 06 concern the determination of total and respirable dust at workplaces by the filtration-weighing method — and it is they that are cited in workplace environment testing. Sheet 7 concerns something else: dust in WASTE GASES, i.e. emission from a stationary source. Confusing these sheets is easy, because the series number and the first elements of the title are common, and the difference begins only in the third element. A laboratory that enters "PN-Z-04030-7" for testing air at a workplace cites a document outside the scope.

THREE TYPES OF MEASUREMENT — AND THIS IS THE ESSENCE OF THIS STANDARD. The card lists requirements for accurate, technical and indicative measurements. These are not synonyms or degrees of care of the person performing them: they are three different sets of requirements, on which depends how many measurement axes and points must be covered and what uncertainty the result carries. Citing the standard number alone without indicating the type of measurement does not yet say what was actually done.

REQUIREMENTS FOR THE MEASUREMENT SITE. In Poland the standard is the basic document deciding where a measurement cross-section may be located in a duct. A trade study devoted to measurement sites lists that the standard specifies: the location of the measurement cross-section, the conditions required for chimney flues discharging to the atmosphere, the rules for selecting the measurement cross-section when meeting these conditions is impossible, and the minimum number of measurement axes — and on that depends the number of sampling ports that must be made in the duct. The latter has direct investment consequences: ports are drilled in an existing stack and cannot be "added" during the measurement.

RELATIONSHIP WITH THE EUROPEAN METHOD. For low dust concentrations PN-EN 13284-1 applies — the European reference method for concentrations below 50 mg/m³, described separately in this database. The Polish regulation on emission measurements permits PN-EN 13284-1 or PN-Z-04030-7 for checking continuous measurements, which means that both documents live in parallel, each in its own concentration range: the national standard starts from 0.001 g/m³, i.e. from 1 mg/m³, and reaches 100 g/m³, so it also covers concentrations much higher than the range of the European method.

CALIBRATION OF AUTOMATIC MEASUREMENTS. The scope explicitly permits the use of this method for the calibration of automatic measurements. For a plant with an installed continuous dust monitor this means that the manual gravimetric measurement is the reference method against which the readings of the instrument are checked — not a test competing with it.

WHAT WE DO NOT GIVE. We do not have the text of the standard — PKN makes it available for a fee (36 pages, KT 280 Air Quality, ICS 13.040.40, publication date 30-12-1994). Therefore WE DO NOT GIVE: specific distances of the measurement cross-section from flow disturbances, the minimum number of axes and points for the individual types of measurement, the dimensions of the ports, formulas for the mass flow rate or limit values of errors. All these numbers are the content of the standard and its annexes.

Method principle

A probe ending in a nozzle is inserted through a port in the duct wall and a stream of gas is drawn through a filter element on which the dust is retained. The condition for correctness is isokinetic sampling: the velocity of the gas entering the nozzle must correspond to the velocity of the gas in the duct at that point, otherwise the stream separates on particles of different inertia and the sample ceases to be representative. The mass of dust is determined by weighing the filter element before and after the measurement, and the concentration — by relating this mass to the volume of gas passed, converted to reference conditions. The dust mass flow rate is calculated from the concentration and the volumetric flow rate of the gases in the duct. The standard divides measurements into accurate, technical and indicative, setting different requirements for each of them; it also contains auxiliary tables and diagrams of typical measuring systems.

Applications

Key parameters

ParameterValue
Concentration rangefrom 0.001 to 100 g/m³ (i.e. from 1 mg/m³ to 100 g/m³) — from the PKN catalogue card
Type of measurementTHREE types with different requirements: accurate, technical, indicative — citing the standard alone does not say which was used
Nature of the methodManual, gravimetric; permitted for the calibration of automatic measurements
Measurement siteThe standard specifies the location of the cross-section, the conditions for flues discharging to the atmosphere, the procedure when the conditions cannot be met, and the minimum number of measurement axes — the number of ports depends on it
LIMIT OF SCOPEWaste gases, NOT air at workplaces — dust at workplaces is covered by sheets 05 and 06 of the same series
Parallel documentPN-EN 13284-1 for low concentrations (below 50 mg/m³); the regulation on emission measurements permits PN-EN 13284-1 or PN-Z-04030-7 for checking continuous measurements
Numerical values from the content of the standardWE DO NOT GIVE THEM — we do not have the text of the standard (36 pages, KT 280 Air Quality, publication 30-12-1994)

Standard

Standard number
PN-Z-04030-7:1994
Title (PL)
Ochrona czystości powietrza -- Badania zawartości pyłu -- Pomiar stężenia i strumienia masy pyłu w gazach odlotowych metodą grawimetryczną
Title (EN)
Air purity protection — Tests for dust content — Measurement of dust concentration and mass flow rate in waste gases by the gravimetric method

Step-by-step procedure

  1. Establishing the type of measurement

    Accurate, technical or indicative — further requirements depend on this. The type is recorded in the report.

  2. Selection of the measurement cross-section

    In accordance with the requirements of the standard regarding the location of the cross-section; when they cannot be met, the standard gives rules for the substitute procedure.

  3. Preparation of the filter element

    Drying and weighing before the measurement.

  4. Measurement of gas parameters

    Velocity, temperature, pressure and humidity in the cross-section — data for selecting the nozzle and for calculations.

  5. Isokinetic sampling

    Suction through the nozzle at a velocity corresponding to the velocity of the gas at the sampling point, at points distributed along the measurement axes.

  6. Weighing and calculation

    Re-weighing of the filter element, calculation of the concentration at reference conditions and of the dust mass flow rate. WE DO NOT GIVE THE FORMULAS AND LIMIT VALUES — they are in the content of the standard.

  7. Report

    Full designation of the standard with the year, type of measurement, location of the cross-section, number of axes and points, conditions in the duct.

Required equipment and apparatus

EquipmentExampleIndicative price
Isokinetic sampling setProbe with nozzle, filter element, suction system with measurement of gas volume—
Instruments for measuring gas parameters in the ductVelocity, temperature, static pressure, humidity — needed to convert the volume to reference conditions and to establish isokinetic conditions—
Analytical balanceWeighing of the filter element before and after the measurement—
Measurement ports in the ductThe number follows from the minimum number of measurement axes specified in the standard—

Reagents, media and consumables

ReagentCASDetails
No reagents—Gravimetric method — result from the difference in mass of the filter element

Health and safety (OHS)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-Z-04030-7:1994 — “Air purity protection — Tests for dust content — Measurement of dust concentration and mass flow rate in waste gases by the gravimetric method”.

How does this method work?

A probe ending in a nozzle is inserted through a port in the duct wall and a stream of gas is drawn through a filter element on which the dust is retained. The condition for correctness is isokinetic sampling: the velocity of the gas entering the nozzle must correspond to the velocity of the gas in the duct at that point, otherwise the stream separates on particles of different inertia and the sample ceases to be representative.

What is the measuring range and accuracy?

Concentration range: from 0.001 to 100 g/m³ (i.e. from 1 mg/m³ to 100 g/m³) — from the PKN catalogue card; Type of measurement: THREE types with different requirements: accurate, technical, indicative — citing the standard alone does not say which was used; Nature of the method: Manual, gravimetric; permitted for the calibration of automatic measurements; Measurement site: The standard specifies the location of the cross-section, the conditions for flues discharging to the atmosphere, the procedure when the conditions cannot be met, and the minimum number of measurement axes — the number of ports depends on it.

How long does the test take?

The procedure comprises 7 steps. The standard does not give a duration for every stage — the laboratory's own procedure decides.

What equipment is required?

Isokinetic sampling set, Instruments for measuring gas parameters in the duct, Analytical balance, Measurement ports in the duct.

Where is this test used?

Measurements of dust emission from stationary sources — boiler houses, heating plants, industrial installations; Calibration and checking of automatic dust monitors installed on flue gas ducts; Assessment of the effectiveness of dedusting equipment — measurement upstream and downstream of the equipment; Design of measurement sites: choice of cross-section, number of axes, number and location of ports; Measurements at concentrations higher than the range of PN-EN 13284-1 (the national standard reaches 100 g/m³).

What safety precautions apply?

The measurement is carried out on an operating flue gas duct — hot gases, risk of burns, work often at height at the stack; Waste gases contain carbon monoxide and other toxic substances — monitoring of the atmosphere and protection of the team are required; Opening a port on a duct under overpressure causes an ejection of hot gas and dust; SUBSTANTIVE NOTE: citing this standard for testing dust at a workplace is citing a document outside the scope — sheets 05 and 06 of the PN-Z-04030 series are appropriate there.

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-Z-04030-7.