🔧 Helium Leak Test

Automotive PN-EN 1779

In short

Detection and location of leaks in components and installations using helium leak detector (mass spectrometer). The test is performed according to PN-EN 1779:2004; Minimum detectable leak (vacuum): 1 × 10⁻¹² mbar·L/s. The procedure comprises 10 steps (about 31 min–2 h 25 min in total); it is used for: Leak testing of automotive air conditioning systems (R134a, R1234yf), Quality control of fuel injectors and fuel pumps (automotive), Leak testing of vacuum chambers and particle accelerators.

At a glance

  • Standard: PN-EN 1779:2004
  • Category: Automotive
  • Procedure steps: 10
  • Total time of stages: 31 min–2 h 25 min
  • Minimum detectable leak (vacuum): 1 × 10⁻¹² mbar·L/s
  • Minimum detectable leak (sniffing): 1 × 10⁻⁹ mbar·L/s
  • Tracer gas: Helium (⁴He), atomic mass 4

Overview

Helium leak testing (HLT) is the most sensitive leak detection method, achieving sensitivity on the order of 10⁻¹² mbar·L/s. Standard PN-EN 1779 defines criteria for selecting leak testing method and technique depending on required sensitivity, object size and test conditions. Helium is an ideal tracer gas — it is light, chemically inert, non-toxic, non-flammable, and its content in the atmosphere is only ~5 ppm, ensuring low background level.

The method is widely used in the automotive industry (air conditioning systems, radiators, fuel injectors, fuel tanks), aerospace (cabin sealing, pressure vessels), vacuum (chambers, scientific apparatus), refrigeration and medical (implants, sterile packaging). Standard PN-EN 1779 classifies leak testing methods from A (highest sensitivity — vacuum helium) to I (lowest — bubble method).

Helium techniques are divided into: integral vacuum method (tested object in vacuum chamber, helium inside), local vacuum method (suction probe on surface), pressure method with sniffing probe (helium inside, sniffer probe outside) and accumulation method (helium collection in closed volume). Each technique has different sensitivity and application.

Helium leak detectors are based on magnetic mass spectrometer tuned to mass 4 (⁴He). Main manufacturers are Pfeiffer Vacuum (ASM series), Agilent (HLD series) and Leybold. Device cost is 100 000–200 000 PLN.

Method principle

Helium detector contains magnetic mass spectrometer selectively tuned to atomic mass 4 (⁴He). In vacuum method: tested object is filled with helium, placed in vacuum chamber connected to detector — helium penetrating through leak is detected by spectrometer. In sniffing method: object filled with helium under pressure is scanned with sniffing probe — helium escaping through leak is sucked into detector. Vacuum method sensitivity reaches 10⁻¹² mbar·L/s, sniffing — 10⁻⁹ mbar·L/s.

Applications

Key parameters

ParameterValue
Minimum detectable leak (vacuum)1 × 10⁻¹² mbar·L/s
Minimum detectable leak (sniffing)1 × 10⁻⁹ mbar·L/s
Tracer gasHelium (⁴He), atomic mass 4
Helium concentration in atmosphere~5 ppm (low background)
Test pressure0.1–30 bar (depending on application)
Detector response time< 1 s (typically)

Standard

Standard number
PN-EN 1779:2004
Title (PL)
Badania nieniszczące — Badania szczelności — Kryteria wyboru metody i techniki
Title (EN)
Non-destructive testing — Leak testing — Criteria for method and technique selection

Step-by-step procedure

  1. Object preparation

    Clean tested element from contaminants (grease, dust). Close all technological openings. Check connections.

    ⏱ Time: 10–30 min

  2. Detector calibration

    Connect reference calibrator (standard leak). Check detector reading — deviation max ±20% of certified value.

    ⏱ Time: 5 min

  3. Technique selection

    Select technique for requirements: integral vacuum (highest sensitivity), sniffing (localization), pressure (large objects).

  4. Filling with helium

    Fill object with helium (or He/N₂ mixture) to test pressure. For vacuum method — place object in chamber and pump down.

    ⏱ Time: 5–30 min

  5. Background stabilization

    Wait for detector background signal stabilization. For vacuum method — stabilize chamber vacuum < 10⁻² mbar.

    ⏱ Time: 5–15 min

  6. Integral measurement

    Monitor detector signal. Signal increase above background indicates leak. Record leak value in mbar·L/s.

    ⏱ Time: 1–5 min

  7. Location (optional)

    For sniffing method: scan object surface filled with helium with sniffing probe. Signal increase indicates leak location.

    ⏱ Time: 5–60 min

  8. Calibration verification

    After measurements, check calibration again with reference calibrator. Drift > 20% disqualifies series.

  9. Result assessment

    Compare measured leak with acceptance criterion. Object tight/leaking. For location — mark leak site.

  10. Documentation

    Prepare test report: object identification, technique, test pressure, result, criterion, environmental conditions.

Required equipment and apparatus

EquipmentExampleIndicative price
Helium leak detectorPfeiffer ASM 340, Pfeiffer ASM 310, Agilent HLD PD03, Leybold Phoenix L300i100 000–200 000 PLN
Test vacuum chamberSteel chamber with connections, dedicated to tested element geometry10 000–100 000 PLN (depending on size)
Auxiliary vacuum pumpTurbomolecular pump + backing pump (dry screw)20 000–50 000 PLN
Sniffing probe (sniffer)Pfeiffer PS 400, Agilent sniffer probe3 000–8 000 PLN
Leak calibrator (standard leak)Pfeiffer TL7, Agilent standard leak 10⁻⁸ mbar·L/s5 000–15 000 PLN
Helium cylinder (5.0)Helium purity 99.999%, cylinder 50 L / 200 bar, Air Liquide / Linde800–1 500 PLN / cylinder

Reagents, media and consumables

ReagentCASDetails
Helium gas (purity 5.0)7440-59-7Purity ≥ 99.999%, as tracer gas for filling tested objects
Helium/nitrogen mixture (10% He)Cheaper alternative to pure helium — used in large installations
Reference calibratorCalibrated helium leak with certificate (e.g. 10⁻⁸ mbar·L/s ± 15%)

Health and safety (OHS)

Frequently asked questions

Which standard describes this test?

The test is performed according to PN-EN 1779:2004 — “Non-destructive testing — Leak testing — Criteria for method and technique selection”.

How does this method work?

Helium detector contains magnetic mass spectrometer selectively tuned to atomic mass 4 (⁴He). In vacuum method: tested object is filled with helium, placed in vacuum chamber connected to detector — helium penetrating through leak is detected by spectrometer.

What is the measuring range and accuracy?

Minimum detectable leak (vacuum): 1 × 10⁻¹² mbar·L/s; Minimum detectable leak (sniffing): 1 × 10⁻⁹ mbar·L/s; Tracer gas: Helium (⁴He), atomic mass 4; Helium concentration in atmosphere: ~5 ppm (low background).

How long does the test take?

The times given for the individual stages add up to approximately 31 min–2 h 25 min. The procedure comprises 10 steps.

What equipment is required?

Helium leak detector, Test vacuum chamber, Auxiliary vacuum pump, Sniffing probe (sniffer), Leak calibrator (standard leak), Helium cylinder (5.0). Indicative cost of the core instrument (Helium leak detector): 100 000–200 000 PLN.

Where is this test used?

Leak testing of automotive air conditioning systems (R134a, R1234yf); Quality control of fuel injectors and fuel pumps (automotive); Leak testing of vacuum chambers and particle accelerators; Electronic enclosure sealing (IP67/IP68); Leak testing of refrigeration and cryogenic installations; Sterile packaging control in pharmaceutical and medical industries; Testing of pressure vessels and pipelines.

What safety precautions apply?

Helium — asphyxiant gas at high concentrations (displaces oxygen), room ventilation; Vacuum chambers — implosion risk, do not open under vacuum without procedure; Test pressure — observe maximum working pressure of object; Gas cylinders — secure against tipping, store vertically; Helium is non-flammable and non-toxic, but in closed rooms can displace oxygen.

Which laboratory can perform this test?

The test is performed by laboratories accredited to ISO/IEC 17025. On LabCoda you can find them by the standard number PN-EN 1779.

🔍 Find a laboratory performing this test