🇵🇱 PODHALAŃSKI SZPITAL SPECJALISTYCZNY PL

PCA AB 595 • Nowy Targ, Poland • 27 methods

Water & wastewaterMicrobiology

PODHALAŃSKI SZPITAL SPECJALISTYCZNY is a laboratory accredited by PCA under number AB 595 (Nowy Targ, Poland). Its accreditation scope covers 27 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Water, Water intended for human consumption, Swimming pool water, Water intended for human consumption, Faeces, Faecal swab. Most frequently used techniques: Membrane filtration method, Spectrophotometric method, Nephelometric method.

At a glance

  • Accreditation number: PCA AB 595
  • Methods in scope: 27
  • Types of test objects: 4
  • Techniques used: 9
  • City: Nowy Targ, Poland
Accreditation number
AB 595
Accreditation body
PCA
Address
im. Jana Pawła II w Nowym Targu, ul. Szpitalna 14, 34-400 Nowy Targ, ZESPÓŁ LABORATORIÓW BADAWCZYCH
City
Nowy Targ, Poland

What this laboratory tests (4)

Analytical techniques used (9)

Laboratory locations

Certificate information

Issue date
14.03.2025
Issue no.
23

Accreditation scope — test methods (27)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Water, Water intended for human consumption Ammonium ion concentration
Range (0,020 - 6,44) mg/l
Spectrophotometric method PN-ISO 7150-1: 2002
2 Water, Water intended for human consumption Colour PN-EN ISO 7887: 2012
3 Water, Water intended for human consumption
Range (5 - 70) mg/l (Pt)
Visual method +Ap1:2015-06 Metoda D
4 Water, Water intended for human consumption Nitrate concentration
Range (1,0 - 110) mg/l
Spectrophotometric method PN-82/C-04576/08
5 Water, Water intended for human consumption Nitrite concentration
Range (0,040 - 5,0) mg/l
Spectrophotometric method PN-EN 26777: 1999
6 Water, Water intended for human consumption Total iron concentration
Range (0,010 - 8) mg/l
Spectrophotometric method PN-ISO 6332: 2001 +Ap1:2016-06
7 Water, Water intended for human consumption Electrical conductivity
Range (74 - 3500) μS/cm
Conductometric method PN-EN 27888:1999
8 Water, Water intended for human consumption Turbidity
Range (0,20 - 40) NTU
Nephelometric method PN-EN ISO 7027-1: 2016-09
9 Water, Water intended for human consumption pH
Range 4,0 - 10,0
Potentiometric method PN-EN ISO 10523: 2012
10 Water, Water intended for human consumption Permanganate index
Range (0,50-10) mg/l O2
Titrimetric method PN-EN ISO 8467: 2001
11 Water intended for human consumption Sampling for chemical and physical testing (including sensory testing) P N-ISO 5667-5:2017-10
12 Swimming pool water Turbidity
Range (0,20 - 40) NTU
Nephelometric method PN-EN ISO 7027-1: 2016-09
13 Swimming pool water Nitrate concentration
Range (1,0 - 110) mg/l
Spectrophotometric method PN-82/C-04576/08
14 Swimming pool water Permanganate index
Range (0,50 - 10) mg/l O2
Titrimetric method PN-EN ISO 8467: 2001
15 Water, Water intended for human consumption Count of microorganisms on nutrient agar at 36°C and 22°C Plate method, pour plate PN-EN ISO 6222: 2004
16 Water, Water intended for human consumption Enterococci count Membrane filtration method PN-EN ISO 7899-2: 2004
17 Water, Water intended for human consumption Clostridium perfringens count including spores Membrane filtration method PN-EN ISO 14189: 2016-10
18 Water, Water intended for human consumption Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266: 2009
19 Water, Water intended for human consumption Escherichia coli and coliform bacteria count Membrane filtration method PN-EN ISO 9308-1: 2014-12 +A1:2017-04
20 Water, Water intended for human consumption Count of bacteria of the genus Legionella
Matrix A; Procedure 5 (medium A), 7 (medium C-GVPC) Matrix B; Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
21 Water intended for human consumption Sampling for microbiological testing P N-EN ISO 19458:2007
22 Swimming pool water Escherichia coli and coliform bacteria count Membrane filtration method PN-EN ISO 9308-1: 2014-12 +A1:2017-04
23 Swimming pool water Microorganism count on nutrient agar at 36°C Plate method, pour plate PN-EN ISO 6222: 2004
24 Swimming pool water Coagulase-positive staphylococci count Membrane filtration method PB/HK/1, wyd. 2 z 18.10.2004 r. w oparciu o wydawnictwo metodyczne PZH 2002r. „Metodyka izolacji gronkowców ze środowiska wodnego”
25 Swimming pool water Pseudomonas aeruginosa count Membrane filtration method PN-EN ISO 16266:2009
26 Swimming pool water Count of bacteria of the genus Legionella
Matrix B; Procedure 7 (medium C-GVPC)
Membrane filtration method PN-EN ISO 11731:2017-08 +Ap1:2019-12
27 Faeces, Faecal swab Presence of rods of the genera, Salmonella sp., Shigella sp., Salmonella Enteritidis, Shigella sonnei Culture method supplemented with biochemical and serological tests PB/LB/1 wyd. 5 z 18.06.2018 r. w oparciu o „Rekomendacje laboratoryjnej diagnostyki zakażeń przewodu pokarmowego bakteriami rosnącymi w warunkach tlenowych oraz mikroaerofilnych” NIZP PZH i KIDL 2015 r.

Reference standards (21)

+Ap1:2015-06 Metoda D
P N-EN ISO 19458:2007
P N-ISO 5667-5:2017-10
PB/HK/1, wyd. 2 z 18.10.2004 r. w oparciu o wydawnictwo metodyczne PZH 2002r. „Metodyka izolacji gronkowców ze środowiska wodnego”
PB/LB/1 wyd. 5 z 18.06.2018 r. w oparciu o „Rekomendacje laboratoryjnej diagnostyki zakażeń przewodu pokarmowego bakteriami rosnącymi w warunkach tlenowych oraz mikroaerofilnych” NIZP PZH i KIDL 2015 r.
PN-82/C-04576/08
PN-EN 26777: 1999
PN-EN 27888:1999
PN-EN ISO 10523: 2012
PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-EN ISO 14189: 2016-10
PN-EN ISO 16266: 2009
PN-EN ISO 16266:2009
PN-EN ISO 6222: 2004
PN-EN ISO 7027-1: 2016-09
PN-EN ISO 7887: 2012
PN-EN ISO 7899-2: 2004
PN-EN ISO 8467: 2001
PN-EN ISO 9308-1: 2014-12 +A1:2017-04
PN-ISO 6332: 2001 +Ap1:2016-06
PN-ISO 7150-1: 2002

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AB%20595