PCA AP 078 • Wrocław, Poland • 5 calibration items

Metrology & calibration

Politechnika Wrocławska is a calibration laboratory accredited by PCA under number AP 078 (Wrocław, Poland). Its accreditation scope covers 5 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electric field strength meters, Magnetic field strength meters, Magnetic induction meters, Electrostatic field strength meters. Most frequently used calibration principles: Internal procedure; Indirect method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 078
  • Calibration items in scope: 5
  • Types of calibrated items: 7
  • Calibration principles used: 1
  • City: Wrocław, Poland
  • Valid until: 22-09-2029
Accreditation number
AP 078
Accreditation body
PCA
Address
ul. Janiszewskiego 9, 50-372 Wrocław
City
Wrocław, Poland
Division
Department of Telecommunications and Teleinformatics, Electromagnetic Field Standards and Metrology Laboratory
Valid until
22-09-2029

What this laboratory calibrates (7)

Calibration principles (1)

Laboratory locations

Certificate information

Issue date
14.10.2026
Issue no.
18
Certificate date
27.06.2022
Accreditation cycle
01.09.2025 — 22.09.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (5)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Meters for measuring magnetostatic fields
Magnetic induction meters
Calibration — Magnetic quantities
0 Hz — 0,01 kA/m to 10 kA/m · CMC 2,8 % 0 Hz — 10 kA/m to 1000 kA/m · CMC 1,0 %
Magnetic quantities
Internal procedure; Indirect method; At permanent location (S) PrW-1, PrW-4 based on IEEE 1309-2013
2 Magnetic field strength meters
Magnetic induction meters
Calibration — Electromagnetic quantities
50 Hz — 0,1 A/m to 50 kA/m · CMC 2,8 % 1 Hz to 1000 Hz — 0,01 A/m to 10 kA/m · CMC 2,8 % 0,001 MHz to 1 MHz — 0,1 A/m to 250 A/m · CMC 5 % 1 MHz to 10 MHz — 0,001 A/m to 200 A/m · CMC 5 % 10 MHz to 100 MHz — 0,001 A/m to 20 A/m · CMC 5 %
Electromagnetic quantities
Internal procedure; Indirect method; At permanent location (S) PrW-1, PrW-4 based on IEEE 1309-2013
3 Electrostatic field strength meters
Electric field strength meters
Magnetic field strength meters
Calibration — Electromagnetic quantities
Field E, 0 MHz to 50 Hz — 10 V/m to 50kV/m · CMC 2,8 % Field E, 0,01 kHz to 100 kHz — 1 V/m to 2 kV/m · CMC 2,8 % Field E, 0,01 MHz to 220 MHz — 0,001 V/m to 2000 V/m · CMC 5 % Field E, 10 MHz to 1000 MHz — 0,001 V/m to 1000 V/m · CMC 5 % Field H, 0,01 MHz to 220 MHz — 0,3 mA/m to 5 A/m · CMC 5 % Field H, 10 MHz to 1000 MHz — 3 mA/m to 2,5 A/m · CMC 5 %
Electromagnetic quantities
Internal procedure; Indirect method; At permanent location (S) PrW-2, PrW-4 based on IEEE 1309-2013
4 Electric field strength meters
Power density meters
Calibration — Electromagnetic quantities
1 GHz to 10 GHz — 0,00001 W/m² to 50 W/m²; 0,06 V/m to 137 V/m · CMC 15 % 10 GHz to 20 GHz — 0,001 W/m² to 50 W/m²; 0,6 V/m to 137 V/m · CMC 25 % 20 GHz to 50 GHz — 0,001 W/m² to 50 W/m²; 0,6 V/m to 137 V/m · CMC 35 % 50 GHz to 90 GHz — 0,001 W/m² to 0,5 W/m²; 0,6 V/m to 14 V/m · CMC 38 %
Electromagnetic quantities
Internal procedure; Indirect method; At permanent location (S) PrW-3, PrW-4 based on IEEE 1309-2013
5 Induced current meters Calibration — Electromagnetic quantities
0,0001 MHz to 110 MHz — 0,001 A to 1,5 A · CMC 10 %
Electromagnetic quantities
Internal procedure; Indirect method; At permanent location (S) PrW-5, PrW-4 based on IEEE 1309-2013

Reference standards (6)

IEEE 1309-2013
PrW-1
PrW-2
PrW-3
PrW-4
PrW-5

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20078